PCC-00105: Keyword WORK required here by ANSI

PCC-00105: Keyword WORK required here by ANSI

Cause: An Oracle extension to the ANSI or ISO SQL standard was used. Specifically, the keyword WORK was used in a COMMIT or ROLLBACK statement. For example, the offending code might look like: EXEC SQL COMMIT WORK RELEASE; This informational message is issued by the FIPS Flagger when FIPS=YES.

Action: No action required. However, for ANSI or ISO compliance, do not use the keyword WORK.